Evaluation of the Failure and Reinforcement of the Foundation in a 20 Storey Residential Building

dc.contributor.authorLópez Gayarre, Fernando 
dc.contributor.authorPrendes Gero, María Belén 
dc.contributor.authorÁlvarez Fernández, Martina Inmaculada 
dc.contributor.authorRamos López, Francisco Luis 
dc.contributor.authorNoval Muñiz, Jorge
dc.date.accessioned2024-11-15T12:20:13Z
dc.date.available2024-11-15T12:20:13Z
dc.date.issued2013
dc.identifier.citationInternational Journal of Construction Engineering and Management, 2(1), p. 23-31 (2013); doi:10.5923/j.ijcem.20130201.04
dc.identifier.urihttps://hdl.handle.net/10651/75682
dc.description.abstractIn this study, we present the results of the forensic analysis and solution proposed for the foundation of a 20-storey building located in the center of the city of Oviedo (Spain), built between 1957 and 1962, and renovated in 2002. During a probe carried out in order to evaluate the original foundation, it was observed that the resistance of the ground was slightly less than that considered for the calculation, and therefore the foundation of the building had to be reinforced. In this paper, we present a detailed description of the problem; determine the source of the failure, present the solution adopted and the constructive process followed. After evaluating different solutions, we opted to construct caissons. In this manner, the foundation of the building was moved to a level with a more resistant layer of ground. The focus of this study is to present as a main cause of the failure the infiltration of sludge waters coming from a manifold located in the surrounding area of the building, which altered the subsoil and caused it to lose resistance. Also relevant is the constructive solution adopted to solve the problem. This study gives a detailed description of the construction process followed in order to be able to replace the original footing by other footing located at a depth of -3.75 m from the first level.Finally, we present the findings derived from the analysis and resolution of the problem.spa
dc.format.extentp. 23-31spa
dc.language.isoengspa
dc.publisherScientific & Academic Publishingspa
dc.relation.ispartofInternational Journal of Construction Engineering and Management, 2(1)spa
dc.rights© 2012 Scientific & Academic Publishing.
dc.rightsCC Reconocimiento - No Comercial 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subjectForensic Analysisspa
dc.subjectSingle Footingspa
dc.subjectCaissonsspa
dc.subjectPillar Supportsspa
dc.titleEvaluation of the Failure and Reinforcement of the Foundation in a 20 Storey Residential Buildingspa
dc.typejournal articlespa
dc.identifier.doi10.5923/j.ijcem.20130201.04
dc.rights.accessRightsopen access
dc.type.hasVersionVoRspa