Sensorless Unbalance Modelling and Estimation as an Ancillary Service for LV 4-Wire/3-Phase Power Converters

dc.contributor.authorSuárez González, Andrés 
dc.contributor.authorGarcía Fernández, Pablo 
dc.contributor.authorNavarro Rodríguez, Ángel 
dc.contributor.authorVilla Fernández, Geber 
dc.contributor.authorCano Rodríguez, José Manuel 
dc.date.accessioned2019-05-23T11:20:39Z
dc.date.available2019-05-23T11:20:39Z
dc.date.issued2019
dc.identifier.citationIEEE Transactions on Industry Applications (2019) doi:10.1109/TIA.2019.2918046
dc.identifier.issn0093-9994
dc.identifier.issn1939-9367
dc.identifier.urihttp://hdl.handle.net/10651/51285
dc.description.abstractThis paper describes a method to provide LV four-wire three-phase power converters with the capability of unbalance estimation as an ancillary service to the main role that they play in the distribution system (distributed generator, energy storage system, drive, etc). Typically, dedicated grid/load current sensors are needed to effectively comply with unbalance compensation tasks, increasing system cost and reducing reliability. This is due to the difficulties that arises in the extraction of the zero and negative voltage components from the voltages at the point of common coupling, such as the inadequate resolution of full-scaled voltage sensors and limited spectral separation. In this paper, the proposed method does not rely on additional sensors to those typically used in VSCs, and in any case, those sensors are limited to the point of connection of the power converter. Impedance estimation only using converter-side current sensors is implemented by adding a high frequency voltage excitation over the fundamental command. A new model approach is proposed for the real-time extraction of system impedance using a complex-valued compact form. Considering the voltage source at that frequency to be unique in the grid, it will be proved the impedance can be estimated and, thus, the resulting negative sequence current which is used for unbalance compensation. For the zero sequence, an especial arrangement of the converter voltage sensors together with a repetitive controller is used.spa
dc.description.sponsorshipThe present work has been partially supported by the predoctoral grants program Severo Ochoa for the formation in research and university teaching of Principado de Asturias PCTI-FICYT under the grant ID BP14-135. This work is also supported in part by the Research, Technological Development and Innovation Program Oriented to the Society Challenges of the Spanish Ministry of Economy and Competitiveness under grants ENE2016-77919-R and DPI2017-89186-R and by the European Union through ERFD Structural Funds (FEDER).spa
dc.language.isoengspa
dc.publisherIEEEspa
dc.relation.ispartofIEEE Transactions on Industry Applicationsspa
dc.rights© 2019 IEEE
dc.titleSensorless Unbalance Modelling and Estimation as an Ancillary Service for LV 4-Wire/3-Phase Power Convertersspa
dc.typejournal articlespa
dc.identifier.doi10.1109/TIA.2019.2918046
dc.relation.projectIDPrincipado de Asturias/ID BP14-135spa
dc.relation.projectIDMINECO/ENE2016-77919-R
dc.relation.projectIDMINECO/DPI2017-89186-R
dc.relation.publisherversionhttp://dx.doi.org/10.1109/TIA.2019.2918046spa
dc.rights.accessRightsopen accessspa
dc.type.hasVersionAM


Ficheros en el ítem

untranslated

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem