Mostrar el registro sencillo del ítem
Development of a genosensor for peanut allergen ARA h 2 detection and its optimization by surface response methodology
dc.contributor.author | Sánchez-Paniagua López, Marta | |
dc.contributor.author | Frutos Cabanillas, Gloria | |
dc.contributor.author | Lobo Castañón, María Jesús | |
dc.contributor.author | López Ruiz, Beatriz | |
dc.date.accessioned | 2015-08-20T10:25:50Z | |
dc.date.available | 2015-08-20T10:25:50Z | |
dc.date.issued | 2014 | |
dc.identifier.citation | Biosensors and Bioelectronics, 62, p. 350-356 (2014); doi:10.1016/j.bios.2014.06.065 | |
dc.identifier.issn | 0956-5663 | |
dc.identifier.uri | http://hdl.handle.net/10651/32548 | |
dc.description.abstract | A new selective electrochemical genosensor has been developed for the detection of an 86-mer DNA peanut sequence encoding part of the allergen Arah2(conglutin-homologprotein).The method is base on a sandwich format,which presents two advantages:it permits shortening the capture probe and avoids labeling of the target.Screen-printed gold electrodes have been used as platformfor the immobilization of oligo nucleotides by the well-knownS–Aubond.Mixedself-assembled monolayers (SAM), including thiol-modified capture probe and mercaptohexanol,were prepared to a chieve an organized, homogeneous and not too compact SAM in which unspecific adsorption of the capture probe would be prevented... | spa |
dc.description.sponsorship | This work has been cofinancied by Project MINECO-13-CTQ- 12-31157 and Project MICINN-08-CTQ-2008-02429 | |
dc.format.extent | p. 350-356 | spa |
dc.language.iso | eng | spa |
dc.publisher | Elsevier | |
dc.relation.ispartof | Biosensors and Bioelectronics, 62 | spa |
dc.rights | © 2014 Elsevier | |
dc.rights | CC Reconocimiento - No comercial - Sin obras derivadas 4.0 Internacional | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Electrochemical genosensor | spa |
dc.subject | Ara h2 peanut allergen | spa |
dc.title | Development of a genosensor for peanut allergen ARA h 2 detection and its optimization by surface response methodology | spa |
dc.type | journal article | |
dc.identifier.doi | 10.1016/j.bios.2014.06.065 | |
dc.relation.projectID | MEC/MINECO-13-CTQ- 12-31157 | |
dc.relation.projectID | MEC/MICINN-08-CTQ-2008-02429 | |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.bios.2014.06.065 | |
dc.rights.accessRights | open access | |
dc.type.hasVersion | AM |
Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Artículos [37321]
-
Investigaciones y Documentos OpenAIRE [8282]
Publicaciones resultado de proyectos financiados con fondos públicos -
Química Física y Analítica [633]