Multiple output AC/DC converter with an internal DC UPS

Author:
Fernández González, Arturo JoséUniovi authority; Sebastián Zúñiga, Francisco JavierUniovi authority; Hernando Álvarez, Marta MaríaUniovi authority; Martín Ramos, Juan AntonioUniovi authority; Corral, Juan
Publication date:
2006
Publisher version:
http://dx.doi.org/10.1109/TIE.2005.862220
Citación:
IEEE Transactions on Industrial Electronics, 53(1), p. 296-304 (2006); doi:10.1109/TIE.2005.862220
Descripción física:
p. 296-304
Abstract:

The usual way to avoid a computer shutdown during a mains failure is to connect an ac uninterruptible power system (UPS). However, there are other possibilities, such as using a dc UPS to obtain the dc output voltages directly from the battery instead of generating an ac voltage to feed the whole power supply. Thus, the topology must operate either from the ac mains or from a battery. A complete design of an ac/dc power supply with an internal dc UPS is presented in this paper. The solution is based on the coupling of the UPS to the main transformer. Moreover, the power supply meets all the requirements needed to be used as an Advanced Technology eXtended (ATX) PC power supply-multiple outputs, power and voltage ratings, size, protections, etc. A prototype has been fully developed and tested as a PC power supply. The autonomy achieved at full power is around 7 minutes

The usual way to avoid a computer shutdown during a mains failure is to connect an ac uninterruptible power system (UPS). However, there are other possibilities, such as using a dc UPS to obtain the dc output voltages directly from the battery instead of generating an ac voltage to feed the whole power supply. Thus, the topology must operate either from the ac mains or from a battery. A complete design of an ac/dc power supply with an internal dc UPS is presented in this paper. The solution is based on the coupling of the UPS to the main transformer. Moreover, the power supply meets all the requirements needed to be used as an Advanced Technology eXtended (ATX) PC power supply-multiple outputs, power and voltage ratings, size, protections, etc. A prototype has been fully developed and tested as a PC power supply. The autonomy achieved at full power is around 7 minutes

URI:
http://hdl.handle.net/10651/19529
ISSN:
0278-0046
DOI:
10.1109/TIE.2005.862220
Collections
  • Artículos [37532]
Files in this item
Métricas
Compartir
Exportar a Mendeley
Estadísticas de uso
Estadísticas de uso
Metadata
Show full item record
Página principal Uniovi

Biblioteca

Contacto

Facebook Universidad de OviedoTwitter Universidad de Oviedo
The content of the Repository, unless otherwise specified, is protected with a Creative Commons license: Attribution-Non Commercial-No Derivatives 4.0 Internacional
Creative Commons Image