RUO Principal

Repositorio Institucional de la Universidad de Oviedo

Ver ítem 
  •   RUO Principal
  • Producción Bibliográfica de UniOvi: RECOPILA
  • Artículos
  • Ver ítem
  •   RUO Principal
  • Producción Bibliográfica de UniOvi: RECOPILA
  • Artículos
  • Ver ítem
    • español
    • English
JavaScript is disabled for your browser. Some features of this site may not work without it.

Listar

Todo RUOComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasxmlui.ArtifactBrowser.Navigation.browse_issnPerfil de autorEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasxmlui.ArtifactBrowser.Navigation.browse_issn

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

AÑADIDO RECIENTEMENTE

Novedades
Repositorio
Cómo publicar
Recursos
FAQs

Absolute quantification of human serum transferrin by species-specific isotope dilution laser ablation ICP-MS

Autor(es) y otros:
Konz Gherghel, IoanaAutoridad Uniovi; Fernández García, BeatrizAutoridad Uniovi; Fernández Sánchez, María LuisaAutoridad Uniovi; Pereiro García, María RosarioAutoridad Uniovi; Sanz Medel, AlfredoAutoridad Uniovi
Fecha de publicación:
2011
Versión del editor:
http://dx.doi.org/10.1021/ac200780b
Citación:
Analytical Chemistry, 83(13), p. 5353-5360 (2011); doi:10.1021/ac200780b
Descripción física:
p. 5353-5360
Resumen:

We report for the first time the absolute quantification of a metalloprotein separated by nondenaturing gel electrophoresis (GE) using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in combination with species-specific isotope dilution mass spectrometry (IDMS). The proposed method is based on the use of an isotopically enriched 57Fe-transferrin complex to quantify natural transferrin (Tf) in human serum samples. First, the saturation process of Tf with natural abundance or isotopically enriched 57Fe was accomplished by using freshly synthesized Fe-citrate solutions. The stability of the metal-protein complex as well as its stoichiometry was investigated by spectrophotometry and ICP-MS, demonstrating a satisfactory stability over a period of at least one month and a molar ratio Fe:Tf of 1.94 ± 0.09, which is close to the expected value of 2. The species-specific IDMS method was compared with external calibration using the Fe-Tf (absolute Tf amount between 2 and 10 μg) and different sample preparation procedures (stained and nonstained gels) as well as two laser ablation strategies (single line ablation in the direction perpendicular or horizontal to the electrophoretic migration) were evaluated. The proposed species-specific GE-LA-ICP-IDMS method was tested for the analysis of a serum certified reference material (ERM-DA470k/IFCC). The results were in good agreement with the certified value with relative standard deviation values in the range of 0.9–2.7% depending on the data treatment procedure used. Furthermore, the analysis time has been drastically reduced in comparison with previous approaches to less than 15 min. The quantification by species-specific GE-LA-ICP-IDMS allowed us to obtain accurate and precise results not only by analyzing the protein spot in the middle position but also in the adjacent ablation line to the center.

We report for the first time the absolute quantification of a metalloprotein separated by nondenaturing gel electrophoresis (GE) using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) in combination with species-specific isotope dilution mass spectrometry (IDMS). The proposed method is based on the use of an isotopically enriched 57Fe-transferrin complex to quantify natural transferrin (Tf) in human serum samples. First, the saturation process of Tf with natural abundance or isotopically enriched 57Fe was accomplished by using freshly synthesized Fe-citrate solutions. The stability of the metal-protein complex as well as its stoichiometry was investigated by spectrophotometry and ICP-MS, demonstrating a satisfactory stability over a period of at least one month and a molar ratio Fe:Tf of 1.94 ± 0.09, which is close to the expected value of 2. The species-specific IDMS method was compared with external calibration using the Fe-Tf (absolute Tf amount between 2 and 10 μg) and different sample preparation procedures (stained and nonstained gels) as well as two laser ablation strategies (single line ablation in the direction perpendicular or horizontal to the electrophoretic migration) were evaluated. The proposed species-specific GE-LA-ICP-IDMS method was tested for the analysis of a serum certified reference material (ERM-DA470k/IFCC). The results were in good agreement with the certified value with relative standard deviation values in the range of 0.9–2.7% depending on the data treatment procedure used. Furthermore, the analysis time has been drastically reduced in comparison with previous approaches to less than 15 min. The quantification by species-specific GE-LA-ICP-IDMS allowed us to obtain accurate and precise results not only by analyzing the protein spot in the middle position but also in the adjacent ablation line to the center.

URI:
http://hdl.handle.net/10651/11042
ISSN:
0003-2700
Identificador local:

20111339

DOI:
10.1021/ac200780b
Colecciones
  • Artículos [37532]
Ficheros en el ítem
Métricas
Compartir
Exportar a Mendeley
Estadísticas de uso
Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Página principal Uniovi

Biblioteca

Contacto

Facebook Universidad de OviedoTwitter Universidad de Oviedo
El contenido del Repositorio, a menos que se indique lo contrario, está protegido con una licencia Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Creative Commons Image