FAQs

High-resolution ICP-MS determination of Ti, V, Cr, Co, Ni, and Mo in human blood and urine of patients implanted with a hip or knee prosthesis

Autor(es) y otros:
Sarmiento González, AlejandroAutoridad Uniovi; Marchante Gayón, Juan ManuelAutoridad Uniovi; Tejerina Lobo, José MaríaAutoridad Uniovi; Paz Jiménez, JoséAutoridad Uniovi; Sanz Medel, AlfredoAutoridad Uniovi
Palabra(s) clave:

Hr-Icp–Ms . Metals Release . Hip and Knee Articular Prosthesis . Blood and Urine Samples

Fecha de publicación:
2008
Versión del editor:
http://dx.doi.org/10.1007/s00216-008-2188-4
Citación:
Analytical and Bioanalytical Chemistry, 391(7), p. 2583-2589 (2008); doi:10.1007/s00216-008-2188-4
Descripción física:
p. 2583-2589
Resumen:

The main components (Ti, V, Cr, Co, Ni, and Mo) of metallic alloys currently used in hip and knee articular prostheses have been simultaneously determined in human whole blood and urine of implanted people by a (HR)-ICP–MS method previously developed in our laboratory. The determination of those elements has been carried out in patients with knee and hip prosthesis and in a group of pre-operation patients without any metallic device in their bodies, used as controls, demonstrating the usefulness of this technique to perform multielement analysis at ppt levels in complex matrices. The concentrations of V, Cr, Co, Ni, and Mo in urine and blood of implanted people turned out to be very similar to those obtained in control patients. However, raised Ti levels could be found both in urine and blood of patients with articular prostheses made or coated with a titanium alloy (Ti6Al4V).

The main components (Ti, V, Cr, Co, Ni, and Mo) of metallic alloys currently used in hip and knee articular prostheses have been simultaneously determined in human whole blood and urine of implanted people by a (HR)-ICP–MS method previously developed in our laboratory. The determination of those elements has been carried out in patients with knee and hip prosthesis and in a group of pre-operation patients without any metallic device in their bodies, used as controls, demonstrating the usefulness of this technique to perform multielement analysis at ppt levels in complex matrices. The concentrations of V, Cr, Co, Ni, and Mo in urine and blood of implanted people turned out to be very similar to those obtained in control patients. However, raised Ti levels could be found both in urine and blood of patients with articular prostheses made or coated with a titanium alloy (Ti6Al4V).

URI:
http://hdl.handle.net/10651/9318
ISSN:
1618-2642; 1618-2650
Identificador local:

51

DOI:
10.1007/s00216-008-2188-4
Colecciones
  • Artículos [37544]
Ficheros en el ítem
Métricas
Compartir
Exportar a Mendeley
Estadísticas de uso
Estadísticas de uso
Metadatos
Mostrar el registro completo del ítem
Página principal Uniovi

Biblioteca

Contacto

Facebook Universidad de OviedoTwitter Universidad de Oviedo
El contenido del Repositorio, a menos que se indique lo contrario, está protegido con una licencia Creative Commons: Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Creative Commons Image