Comparison of the periimplant bone stress distribution on three fixed partial supported prosthesis designs under different loading. A 3D finite element analysis
Subject:
Three-unit bridge
occlusal loading
bone density
tilted implant
cantilever prosthesis
Publication date:
Editorial:
Taylor & Francis
Publisher version:
Citación:
Descripción física:
Abstract:
Despite high success and survival rates of implant-supported prosthesis therapy, biomechanical complications such as periimplant bone resorp- tion continue to exist due to occlusal overloading. The purpose of this article is to analyse and compare the influence of bone density, direction and distribution of the occlusal load and the design of three-unit implant-supported prostheses. Three-dimensional finite element analysis study was developed to evaluate the influence on the periimplant bone stress distribution of three different designs of a 3-unit bridge supported by two implants (intermediate pontic, tilted implant, cantilever pontic), two different bone qualities (D3 and D4), and different loading directions (axial and non-axial) and distributions (uniform and non-uniform). Bridge configuration with intermediate pontic and parallel implants presents the lowest periimplant stress, whereas the highest stress was found on the tilted implant bridge. Bone D3 is biomechanically more favourable than D4. Non-axial and uniform loading conditions produce more peri- implant stress. Distal cantilever and 45° convergent distal tilted implant are the second and third treatment options on a posterior three-unit rehabilitation. Lightening occlusal contacts on the pontic and avoiding non-axial loading, reduce periimplant bone stress. Bone D4 increases periimplant bone strain.
Despite high success and survival rates of implant-supported prosthesis therapy, biomechanical complications such as periimplant bone resorp- tion continue to exist due to occlusal overloading. The purpose of this article is to analyse and compare the influence of bone density, direction and distribution of the occlusal load and the design of three-unit implant-supported prostheses. Three-dimensional finite element analysis study was developed to evaluate the influence on the periimplant bone stress distribution of three different designs of a 3-unit bridge supported by two implants (intermediate pontic, tilted implant, cantilever pontic), two different bone qualities (D3 and D4), and different loading directions (axial and non-axial) and distributions (uniform and non-uniform). Bridge configuration with intermediate pontic and parallel implants presents the lowest periimplant stress, whereas the highest stress was found on the tilted implant bridge. Bone D3 is biomechanically more favourable than D4. Non-axial and uniform loading conditions produce more peri- implant stress. Distal cantilever and 45° convergent distal tilted implant are the second and third treatment options on a posterior three-unit rehabilitation. Lightening occlusal contacts on the pontic and avoiding non-axial loading, reduce periimplant bone stress. Bone D4 increases periimplant bone strain.
Patrocinado por:
Funding This work was supported by the Spanish Economics and Competitiveness Ministry, through grant [AYA2014-57648-P] and [MINECO-18-AYA2017-89121-P] and the Government of the Principality of Asturias (Consejería de Economía y Empleo), through grant [FC-15-GRUPIN14-017].
Collections
- Administración de Empresas [499]
- Artículos [36888]
- Investigaciones y Documentos OpenAIRE [8112]
Files in this item