Analysis and Validation of a Novel Symmetrical Structure for Toroidal Variable Power Inductors in Energy Storage Systems
dc.contributor.author | Saeed Hazkial Gerges, Sarah | |
dc.contributor.author | García García, Jorge | |
dc.date.accessioned | 2024-12-03T08:12:53Z | |
dc.date.available | 2024-12-03T08:12:53Z | |
dc.date.issued | 2024-08-16 | |
dc.identifier.citation | Saeed, S., & Garcia, J. (2024). Analysis and validation of a novel symmetrical structure for toroidal variable power inductors in energy storage systems. IEEE Journal of Emerging and Selected Topics in Power Electronics. https://doi.org/10.1109/JESTPE.2024.3445309 | |
dc.identifier.uri | https://hdl.handle.net/10651/75853 | |
dc.description.abstract | This paper presents an analysis of an alternative variable inductor structure compared to the ones previously proposed in the literature. The inductor is constructed based on a toroidal core and presents some prosperous advantages, which are: a reduced induced voltage in the DC bias control windings, and a symmetrical operation, while making use of the simplicity of a toroidal magnetic core. The proposed variable inductor topology is applied to a specific case study: the design and implementation of a bidirectional boost converter for integration of Battery Energy Storage Systems into DC grids. The variation of the inductance in this application provides an extra degree of freedom in the design which offers twofold improvement to the controlled system. On the one hand, it allows the system to keep the same impedance throughout the operation range. This guarantees that the behavior of the controlled system will remain the same and avoids the need to change the controller tuning and parameters each time the State-Of-Charge of the battery varies. And on the other hand, it enables control over the voltage and current ripple through the battery without the need to install extra capacitor banks. The design, assessment, and experimental procedures of the proposed variable inductor structure for this application case are shown in this paper. The results show an improvement in the performance of the selected case study. | spa |
dc.language.iso | eng | spa |
dc.relation.ispartof | IEEE Journal of Emerging and Selected Topics in Power Electronics | spa |
dc.rights | CC Reconocimiento – No Comercial – Sin Obra Derivada 4.0 Internacional | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Variable inductor | spa |
dc.subject | Distributed airgap | spa |
dc.title | Analysis and Validation of a Novel Symmetrical Structure for Toroidal Variable Power Inductors in Energy Storage Systems | spa |
dc.type | journal article | spa |
dc.identifier.doi | 10.1109/JESTPE.2024.3445309 | |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2022-139479OB-C22/ES/DISEÑO Y CONTROL DE CENTRALES HIDROELECTRICAS FLEXIBLES MEDIANTE HIBRIDACION CON BATERIAS DE 2ª VIDA/ | spa |
dc.relation.projectID | TED2021-129796B-C21 | spa |
dc.relation.projectID | info:eu-repo/grantAgreement/EC/H2020/864459/EU | spa |
dc.relation.publisherversion | https://ieeexplore.ieee.org/document/10638095 | |
dc.rights.accessRights | open access | |