Mostrar el registro sencillo del ítem

Non-linear hygrothermal structural analysis of the elliptical dome of the church in the Universidad Laboral, Gijón, Spain

dc.contributor.authorCoz Díaz, Juan José del 
dc.contributor.authorLozano Martínez-Luengas, Alfonso Gerónimo 
dc.contributor.authorAlonso Martínez, Mar 
dc.contributor.authorÁlvarez Rabanal, Felipe Pedro 
dc.date.accessioned2022-09-14T09:24:05Z
dc.date.available2022-09-14T09:24:05Z
dc.date.issued2022-06-23
dc.identifier.citationInternational Journal of Architectural Heritage (2022); doi: 10.1080/15583058.2022.2089070
dc.identifier.urihttp://hdl.handle.net/10651/64793
dc.description.abstractThe Church of the Laboral University of Gijón has the world’s largest elliptical masonry roof with a 40.8 m major axis. This large structure is vertically self-supported with 20 pairs of masonry ribs crossing each other and horizontally supported by means of two elliptical ring beams at the top of the dome. In order to study this historic building, this paper presents the overall three-dimensional structural numerical analysis of the roof. It includes nonlinearities due to materials, geometry, and contacts between structural elements of the building. Temperature, moisture content, and dead loads are included in the hygrothermal structural analysis of the dome. In this nonlinear numerical analysis displacements, stress, cracking, and crushing are evaluated. The influence of moisture content on the structure performance and other relevant conclusions are presented.spa
dc.description.sponsorshipProyectos financiados por la Fundación para el Fomento en Asturias de la Investigación Científica Aplicada y la Tecnología (FYCIT): AYUD/2021/51328 y GRUPIN-IDI/2018/000221.spa
dc.format.extent10 p.spa
dc.language.isoengspa
dc.relation.ispartofInternational Journal of Architectural Heritagespa
dc.rights© Informa UK Ltd, Taylor & Francis Group
dc.rightsCC Reconocimiento - No Comercial - Sin Obra Derivada 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectHistoric structurespa
dc.subjectmasonryspa
dc.subjectmoisture effectspa
dc.subjectnon-destructive inspectionspa
dc.subjectnonlinear analysisspa
dc.titleNon-linear hygrothermal structural analysis of the elliptical dome of the church in the Universidad Laboral, Gijón, Spainspa
dc.typejournal articlespa
dc.identifier.doi10.1080/15583058.2022.2089070
dc.relation.projectIDAYUD/2021/51328spa
dc.relation.projectIDGRUPIN-IDI/2018/000221spa
dc.relation.publisherversionhttps://doi.org/10.1080/15583058.2022.2089070
dc.rights.accessRightsopen access
dc.type.hasVersionAM


Ficheros en el ítem

untranslated

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

© Informa UK Ltd, Taylor & Francis Group
Este ítem está sujeto a una licencia Creative Commons