Mostrar el registro sencillo del ítem
Rapid evaluation of different perovskite absorber layers through the application of depth profile analysis using glow discharge – Time of flight mass spectrometry
dc.contributor.author | Fernández García, Beatriz | |
dc.contributor.author | Lobo Revilla, Lara | |
dc.contributor.author | Tyagi, P. | |
dc.contributor.author | Stoichkov, V. | |
dc.contributor.author | Kettle, J. | |
dc.contributor.author | Pereiro García, María Rosario | |
dc.date.accessioned | 2019-01-30T07:57:56Z | |
dc.date.available | 2019-01-30T07:57:56Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Talanta, 192, p. 317-324 (2019); doi:10.1016/j.talanta.2018.09.059 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.uri | http://hdl.handle.net/10651/49912 | |
dc.description.sponsorship | Financial support from Horiba Scientific through a research project is gratefully acknowledged. Also, B.F. acknowledges her research contract RYC-2014-14985 to the Spanish Ministry of Economy and Competitiveness through the Ramón y Cajal Program. Authors thank Samuel Gonzalez for his help during the first PGD-ToFMS optimizations. J.K., P.T. and V.S. would like to acknowledge the European Regional Development Fund (ERDF) and the Welsh European Funding Office (WEFO) for funding the 2nd Solar Photovoltaic Academic Research Consortium (SPARCII) which supported this research and the Sêr Cymru National Research Network. | |
dc.format.extent | p. 317-324 | |
dc.language.iso | eng | |
dc.relation.ispartof | Talanta | |
dc.rights | © 2018 Elsevier | |
dc.rights | CC Reconocimiento - No comercial - Sin obras derivadas 4.0 Internacional | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | Scopus | |
dc.source.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85053784328&doi=10.1016%2fj.talanta.2018.09.059&partnerID=40&md5=755d9022637c7039f30e39a1eb26c857 | |
dc.title | Rapid evaluation of different perovskite absorber layers through the application of depth profile analysis using glow discharge – Time of flight mass spectrometry | |
dc.type | journal article | |
dc.identifier.doi | 10.1016/j.talanta.2018.09.059 | |
dc.relation.projectID | RYC-2014-14985 | |
dc.relation.publisherversion | http://dx.doi.org/10.1016/j.talanta.2018.09.059 | |
dc.rights.accessRights | open access | |
dc.type.hasVersion | AM |
Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Artículos [37532]
-
Investigaciones y Documentos OpenAIRE [8365]
Publicaciones resultado de proyectos financiados con fondos públicos -
Química Física y Analítica [635]