Au@Ag SERRS tags coupled to a lateral flow immunoassay for the sensitive detection of pneumolysin

dc.contributor.authorBlanco Covián, Lucía 
dc.contributor.authorMontes García, Verónica
dc.contributor.authorGirard, Alexandre
dc.contributor.authorFernández Abedul, María Teresa 
dc.contributor.authorPérez Juste, Jorge
dc.contributor.authorPastoriza Santos, Isabel
dc.contributor.authorFaulds, Karen
dc.contributor.authorGraham, Duncan
dc.contributor.authorBlanco López, María del Carmen 
dc.date.accessioned2017-01-26T08:20:01Z
dc.date.available2017-01-26T08:20:01Z
dc.date.issued2017
dc.identifier.citationNanoscale, 9(5), p. 2051-2058 (2017); doi:10.1039/C6NR08432J
dc.identifier.urihttp://hdl.handle.net/10651/39400
dc.description.abstractEstablishing a definitive diagnosis of pneumonia using conventional tests is difficult and expensive. Lateral flow immunoassays (LFIAs) are an advantageous point of care (POC) test option, but they have some limitations in terms of detection and quantification. In this work we have developed a lateral flow immunoassay for the ultrasensitive detection of penumolysin employing plasmonic Surface-Enhanced Resonance Raman Scattering (SERRS) tag as labelled probe. The combination of Au@Ag core-shell nanoparticles as plasmonic platform and Rhodamine B Isothiocyanate as Raman reporter has allowed us to fabricate a SERRS tag with high efficiency and reliability. The limit of quantification of the SERRS-based LFIA was 1pg/mL, while the limit of detection was 3.6 pg/mL. This could be a strong foundation for a pneumonia diagnosis test based on pneumolysin detectioneng
dc.description.sponsorshipThis work was supported by the Ministerio de Economía y Competitividad (MINECO, Spain), under the Grant CTQ2013-47396-R, CTQ2014-58826-R, MAT2013-45168-R and MAT2016-77809-R. This study was also financed by the Consejería de Economía y Empleo del Principado de Asturias (Plan de Ciencia, Tecnología e Innovación 2013–2017), under the Grant GRUPIN14-022 and FC-15-GRUPIN14-021. V. M.-G. acknowledges FPU scholarship from the Spanish MINECO. A. G. acknowledges EPSRC (Engineering and Physical Sciences Research Council).
dc.format.extentp. 2051-2058spa
dc.language.isoengspa
dc.publisherRoyal Society of Chemistryspa
dc.relation.ispartofNanoscalespa
dc.rights© 2017 The Royal Society of Chemistry
dc.titleAu@Ag SERRS tags coupled to a lateral flow immunoassay for the sensitive detection of pneumolysineng
dc.typejournal articlespa
dc.identifier.doi10.1039/C6NR08432J
dc.relation.projectIDMINECO/CTQ2013-47396-R
dc.relation.projectIDMINECO/CTQ2014-58826-R
dc.relation.projectIDMINECO/MAT2013-45168-R
dc.relation.projectIDMINECO/MAT2016-77809-R
dc.relation.publisherversionhttp://dx.doi.org/10.1039/C6NR08432Jspa
dc.rights.accessRightsopen access
dc.type.hasVersionAM


Files in this item

untranslated

This item appears in the following Collection(s)

Show simple item record