Mostrar el registro sencillo del ítem
Au@Ag SERRS tags coupled to a lateral flow immunoassay for the sensitive detection of pneumolysin
dc.contributor.author | Blanco Covián, Lucía | |
dc.contributor.author | Montes García, Verónica | |
dc.contributor.author | Girard, Alexandre | |
dc.contributor.author | Fernández Abedul, María Teresa | |
dc.contributor.author | Pérez Juste, Jorge | |
dc.contributor.author | Pastoriza Santos, Isabel | |
dc.contributor.author | Faulds, Karen | |
dc.contributor.author | Graham, Duncan | |
dc.contributor.author | Blanco López, María del Carmen | |
dc.date.accessioned | 2017-01-26T08:20:01Z | |
dc.date.available | 2017-01-26T08:20:01Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Nanoscale, 9(5), p. 2051-2058 (2017); doi:10.1039/C6NR08432J | |
dc.identifier.uri | http://hdl.handle.net/10651/39400 | |
dc.description.abstract | Establishing a definitive diagnosis of pneumonia using conventional tests is difficult and expensive. Lateral flow immunoassays (LFIAs) are an advantageous point of care (POC) test option, but they have some limitations in terms of detection and quantification. In this work we have developed a lateral flow immunoassay for the ultrasensitive detection of penumolysin employing plasmonic Surface-Enhanced Resonance Raman Scattering (SERRS) tag as labelled probe. The combination of Au@Ag core-shell nanoparticles as plasmonic platform and Rhodamine B Isothiocyanate as Raman reporter has allowed us to fabricate a SERRS tag with high efficiency and reliability. The limit of quantification of the SERRS-based LFIA was 1pg/mL, while the limit of detection was 3.6 pg/mL. This could be a strong foundation for a pneumonia diagnosis test based on pneumolysin detection | eng |
dc.description.sponsorship | This work was supported by the Ministerio de Economía y Competitividad (MINECO, Spain), under the Grant CTQ2013-47396-R, CTQ2014-58826-R, MAT2013-45168-R and MAT2016-77809-R. This study was also financed by the Consejería de Economía y Empleo del Principado de Asturias (Plan de Ciencia, Tecnología e Innovación 2013–2017), under the Grant GRUPIN14-022 and FC-15-GRUPIN14-021. V. M.-G. acknowledges FPU scholarship from the Spanish MINECO. A. G. acknowledges EPSRC (Engineering and Physical Sciences Research Council). | |
dc.format.extent | p. 2051-2058 | spa |
dc.language.iso | eng | spa |
dc.publisher | Royal Society of Chemistry | spa |
dc.relation.ispartof | Nanoscale | spa |
dc.rights | © 2017 The Royal Society of Chemistry | |
dc.title | Au@Ag SERRS tags coupled to a lateral flow immunoassay for the sensitive detection of pneumolysin | eng |
dc.type | journal article | spa |
dc.identifier.doi | 10.1039/C6NR08432J | |
dc.relation.projectID | MINECO/CTQ2013-47396-R | |
dc.relation.projectID | MINECO/CTQ2014-58826-R | |
dc.relation.projectID | MINECO/MAT2013-45168-R | |
dc.relation.projectID | MINECO/MAT2016-77809-R | |
dc.relation.publisherversion | http://dx.doi.org/10.1039/C6NR08432J | spa |
dc.rights.accessRights | open access | |
dc.type.hasVersion | AM |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Artículos [36307]
-
Investigaciones y Documentos OpenAIRE [7936]
Publicaciones resultado de proyectos financiados con fondos públicos -
Química Física y Analítica [606]