Halogenated molecularly imprinted polymers for selective determination of carbaryl by phosphorescence measurements

Author:
Álvarez Díaz, AdriánUniovi authority; Costa Fernández, José ManuelUniovi authority; Pereiro García, María RosarioUniovi authority; Sanz Medel, AlfredoUniovi authority
Subject:

Carbaryl . Molecular Imprinting . Room-Temperature Phosphorescence . Biomimetic Optosensing .Water Analysis

Publication date:
2009
Publisher version:
http://dx.doi.org/10.1007/s00216-009-2725-9
Citación:
Analytical and Bioanalytical Chemistry, 394(6), p. 1569-1576 (2009); doi:10.1007/s00216-009-2725-9
Descripción física:
p. 1569-1576
Abstract:

A highly selective molecularly imprinted polymer (MIP) for the recognition of the pesticide carbaryl in water has been synthesized using halogenated bisphenol A compounds as one of the polymeric precursors and carbaryl as the template molecule. On the basis of the heavy-atom effect, both the brominated and the iodinated MIPs allowed analyte detection by room-temperature-phosphorescence measurements. In the presence of an oxygen scavenger (sodium sulphite) the halide, included in the polymeric structure, induced efficient roomtemperature phosphorescence of the analyte (once it had been selectively retained by the MIP). The MIP cavity can be easily regenerated for subsequent sample injections with 2 mL methanol. The optosensing system developed has demonstrated high selectivity for carbaryl, even in the presence of other luminophores that could be unspecifically adsorbed onto the MIP surface. Under optimal experimental conditions, the detection limit for the target molecule was 4 μg/L (3-mL sample injection volume), and the linear range extended up to 1 mg/L of the analyte. Good reproducibility was achieved (a relative standard deviation of 3% was obtained for ten replicates of 150 μg/L carbaryl). The synthesized sensing material showed good stability for at least 3 months after preparation. Finally, the applicability to carbaryl determination in real samples was evaluated through the successful determination of the pesticide in spikedmineral and tap water samples.

A highly selective molecularly imprinted polymer (MIP) for the recognition of the pesticide carbaryl in water has been synthesized using halogenated bisphenol A compounds as one of the polymeric precursors and carbaryl as the template molecule. On the basis of the heavy-atom effect, both the brominated and the iodinated MIPs allowed analyte detection by room-temperature-phosphorescence measurements. In the presence of an oxygen scavenger (sodium sulphite) the halide, included in the polymeric structure, induced efficient roomtemperature phosphorescence of the analyte (once it had been selectively retained by the MIP). The MIP cavity can be easily regenerated for subsequent sample injections with 2 mL methanol. The optosensing system developed has demonstrated high selectivity for carbaryl, even in the presence of other luminophores that could be unspecifically adsorbed onto the MIP surface. Under optimal experimental conditions, the detection limit for the target molecule was 4 μg/L (3-mL sample injection volume), and the linear range extended up to 1 mg/L of the analyte. Good reproducibility was achieved (a relative standard deviation of 3% was obtained for ten replicates of 150 μg/L carbaryl). The synthesized sensing material showed good stability for at least 3 months after preparation. Finally, the applicability to carbaryl determination in real samples was evaluated through the successful determination of the pesticide in spikedmineral and tap water samples.

URI:
http://hdl.handle.net/10651/10895
ISSN:
1618-2642
Identificador local:

20090474

DOI:
10.1007/s00216-009-2725-9
Collections
  • Artículos [37543]
Files in this item
Métricas
Compartir
Exportar a Mendeley
Estadísticas de uso
Estadísticas de uso
Metadata
Show full item record
Página principal Uniovi

Biblioteca

Contacto

Facebook Universidad de OviedoTwitter Universidad de Oviedo
The content of the Repository, unless otherwise specified, is protected with a Creative Commons license: Attribution-Non Commercial-No Derivatives 4.0 Internacional
Creative Commons Image