Mostrar el registro sencillo del ítem

Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry

dc.contributor.authorSolà Vázquez, Auristela 
dc.contributor.authorCosta Fernández, José Manuel 
dc.contributor.authorPereiro García, María Rosario 
dc.contributor.authorSanz Medel, Alfredo 
dc.date.accessioned2013-01-30T10:18:24Z
dc.date.available2013-01-30T10:18:24Z
dc.date.issued2011
dc.identifier.citationAnalytical and Bioanalytical Chemistry, 401(9), p. 1-7 (2011); doi:10.1007/s00216-011-5145-6spa
dc.identifier.issn1618-2642
dc.identifier.urihttp://hdl.handle.net/10651/10358
dc.description.abstractA new prototype based on a microsecond pulsed glow discharge ion source coupled to a time-of-flight mass spectrometer was recently designed, constructed and analytically evaluated in our laboratory for simultaneous collection of elemental and molecular information, and as a gaschromatographic detector of compounds of environmental concern. To investigate further the analytical capabilities of such a new setup, its capability for the determination of element ratios in volatile organic halogenated compounds has been explored. Moreover, compound-independent calibration has been carried out with the prototype as well. The results demonstrated that the intensity ratios (analyte to internal standard) were linear with the corresponding ratio of concentrations. Both for chlorine and bromine (measured in the prepeak) and for BrC (measured in the plateau) the slope was 1 and the intercept was 0. Moreover, detection limits were improved by more than 1 order of magnitude as compared with using external calibration. The applicability of the proposed approach has been demonstrated for the straightforward determination of chloroform in drinking and river waters.spa
dc.format.extentp. 1-7spa
dc.language.isoeng
dc.relation.ispartofAnalytical and Bioanalytical Chemistryspa
dc.rights(c) Analytical and Bioanalytical Chemistry
dc.sourceSCOPUSspa
dc.subjectPulsed Glow Discharge . Time-Of-Flight Mass Spectrometry . Speciation Analysis . Elemental Ratio Determinations . Compound-Independent Calibrationspa
dc.titleElemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometryspa
dc.typejournal article
dc.identifier.local20110831spa
dc.identifier.doi10.1007/s00216-011-5145-6
dc.relation.publisherversionhttp://dx.doi.org/10.1007/s00216-011-5145-6spa


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem