Mostrar el registro sencillo del ítem

Critical comparison of automated purge and trap and solid-phase microextraction for routine determination of volatile organic compounds in drinking waters by GC-MS

dc.contributor.authorLara Gonzalo, Azucena 
dc.contributor.authorSánchez Uría, José Enrique 
dc.contributor.authorSegovia García, Eva
dc.contributor.authorSanz Medel, Alfredo 
dc.date.accessioned2013-01-30T10:07:12Z
dc.date.available2013-01-30T10:07:12Z
dc.date.issued2008
dc.identifier.citationTalanta, 74(5), p. 1455-1462 (2008); doi:10.1016/j.talanta.2007.09.036spa
dc.identifier.issn0039-9140
dc.identifier.urihttp://hdl.handle.net/10651/8279
dc.description.abstractThe use of two automated sample preparation techniques, solid-phase microextraction (SPME) and purge and trap (P&T) systems are critically compared for the GC–MS determination of eight volatile organic compounds (VOCs), including trihalomethanes (THMs), in drinking water samples. Compounds chosen for the comparison are regulated by Spanish and European official guidelines for drinking waters. Experimental parameters investigated for the two sample preparation techniques included SPME type of fibers, SPME modality, P&T gas flow, extraction and desorption times and desorption temperatures. Thus, optimal experimental conditions have been worked out for the SPME and P&T techniques. Under such optimised conditions, detection limits, precision and accuracy were evaluated. Both methods fulfilled the values that the official guidelines establish. The P&T–GC–MS method offers LDs ranged from 0.004 to 0.2 ng mL−1, repeatabilities below 6% and recoveries between 81 and 117%; while LDs ranging from 0.008 to 0.7 ng mL−1, 1–12% R.S.D. and recoveries from 80 to 119% were achieved with the SPME–GC–MS method. Finally, we chose P&T–GC–MS method as the best for this determination and we validate this methodology by its application to the analysis of an Aquacheck Interlaboratory Exercise.spa
dc.format.extentp. 1455-1462spa
dc.language.isoeng
dc.relation.ispartofTalantaspa
dc.rights(c) Talanta
dc.sourceWOKspa
dc.subjectP&T; Di-Spme; Gc–Ms; Thms; Vocs; Water Samplesspa
dc.titleCritical comparison of automated purge and trap and solid-phase microextraction for routine determination of volatile organic compounds in drinking waters by GC-MSspa
dc.typejournal article
dc.identifier.local511spa
dc.identifier.doi10.1016/j.talanta.2007.09.036
dc.relation.publisherversionhttp://dx.doi.org/10.1016/j.talanta.2007.09.036spa


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem