Data Documentation for Electrocatalytic Palladium Nanoclusters as Versatile Indicators of Bioassays: Rapid Electroanalytical Detection of SARS-CoV-2 by Reverse Transcription Loop-Mediated Isothermal Amplification General Information The excel file contains the following tabs: amplification measure, pH measure, measurements PdNCs in solution, LAMP-picodrop, results green, results blue, results red, measurements deposited PdNCs, replicates same electrodes, replicates different electrode, NCs with nitrogen, samples of Covid 19, CV in PBS, CV in NaOH, CV in H2SO4, PdNCs change with pH, stability of PdNCs, synthesis at different T, 0 and 100 copies amplification which correspond to the results shown in the aforementioned article. The data are raw, so if any doubt arises when processing it or additional information is needed about the concentrations or measures used, first author/corresponding author should be contacted. Name of dataset: Data associated to: Electrocatalytic Palladium Nanoclusters as Versatile Indicators of Bioassays: Rapid Electroanalytical Detection of SARS-CoV-2 by Reverse Transcription Loop-Mediated Isothermal Amplification Name of data files in data set: Data associated to: Electrocatalytic Palladium Nanoclusters as Versatile Indicators of Bioassays: Rapid Electroanalytical Detection of SARS-CoV-2 by Reverse Transcription Loop-Mediated Isothermal Amplification Dataset language: English Date the data set was last modified: 12/02/2023 Funder: This work has been supported by the project LIFE of Fondo Supera COVID-19 from Banco de Santander, CRUE and CSIC, as well as by the Spanish Government (MCIN/AEI/10.13039/501100011033) through the I+D+i project PID2020-118376RA-I00, and by the PCTI Program of the Government of the Principality of Asturias and FEDER Program of the European Union (No. AYUD/2021/51289). Also UNIR supported the research, through the collaborative UNIR-UNIOVI project Pneumo.SARS.Detection (2021/2022). E.C.R. thanks for the support of the grant Beatriz Galindo (No. BG20/00027) funded by the Ministry of Universities of the Spanish Government. How to cite data: With the doi generated Methodology for data collection: The data collected in the excel file are the raw data obtained directly from the equipment, in some cases additional information is provided about the treatment or the samples involved. Data collector(s): Alejandro Rodríguez-Penedo Date of data collection: Since July 2021 until October 2022. Person to contact with questions: rodriguezpalejandro@uniovi.es/mtfernandeza@uniovi.es Data entry: 12/02/2024 Software (including version #) used to prepare data set: Excel Ver. 2312 Data processing that was performed: The data was grouped and treated as shown in the corresponding article. As a summary, the first step was to take into account the weighings (when necessary), then the mean and standard deviation of the measurements were obtained, and finally the relevant statistical treatment was carried out to make the graphs or to obtain conclusions from the data. Variables The intensity has been measured in A, the voltage in V, the absorbance in arbitrary units, the pH is dimensionless, the concentration is indicated (usually ng mL-1 or copies mL-1 for amplifications) File Overview There is only one file, although it contains multiple Excel tabs, each one being indicated with the data to which it corresponds