Mostrar el registro sencillo del ítem

Direct µ-flow injection isotope dilution ICP-MS for the determination of heavy metals in oil samples

dc.contributor.authorBettmer, Jörg 
dc.contributor.authorHeilmann, Jens
dc.contributor.authorKutscher, Daniel Jurgen 
dc.contributor.authorSanz Medel, Alfredo 
dc.contributor.authorHeumann, Klaus G.
dc.date.accessioned2013-01-30T10:08:14Z
dc.date.available2013-01-30T10:08:14Z
dc.date.issued2012
dc.identifier.citationAnalytical and Bioanalytical Chemistry, January 2012, Volume 402, Issue 1, pp 269-275; doi:10.1007/s00216-011-5420-6spa
dc.identifier.issn1618-2642
dc.identifier.urihttp://hdl.handle.net/10651/8481
dc.description.abstractThe determination of trace elements in oil samples and their products is of high interest as their presence significantly affects refinery processes and the environment by possible impact of their combustion products. In this context, inductively coupled plasma mass spectrometry (ICP-MS) plays an important role due to its outstanding analytical properties in the quantification of trace elements. In this work, we present the accurate and precise determination of selected heavy metals in oil samples by making use of the combination of μ-flow direct injection and isotope dilution ICP-MS (ICP-IDMS). Spike solutions of 62Ni, 97Mo, 117Sn and 206Pb were prepared in an organic solvent, mixed directly with the diluted oil samples and tested to be fit for purpose for the intended ID approach. The analysis of real samples revealed strong matrix effects affecting the ICP-MS sensitivity, but not the isotope ratio measurements, so that accurate results are obtained by ICP-IDMS. Typical relative standard deviations were about 15% for peak area and peak height measurements, whereas the isotope ratios were not significantly affected (RSD < 2%). The developed method was validated by the analysis of a metallo-organic multi-element standard (SCP-21, typically applied as a calibration standard) and the standard reference material SRM1084a (wear metals in lubricating oil). The obtained results were in excellent agreement with the certified values (recoveries between 98% and 102%), so the proposed methodology of combining μ-flow direct injection and ICP-IDMS can be regarded as a new tool for the matrix-independent, multi-element and reliable determination of trace elements in oil and related organic liquids.spa
dc.format.extentp. 1-7spa
dc.language.isoeng
dc.relation.ispartofAnalytical and Bioanalytical Chemistryspa
dc.rights(c) Analytical and Bioanalytical Chemistry
dc.sourceSCOPUSspa
dc.subjectInductively Coupled Plasma–Mass Spectrometry (Icp-Ms) . Trace Elements . Isotope Dilution Analysis . Μ- Flow Injection . Oil Samples . Direct Analysisspa
dc.titleDirect µ-flow injection isotope dilution ICP-MS for the determination of heavy metals in oil samplesspa
dc.typejournal article
dc.identifier.local20110953spa
dc.identifier.doi10.1007/s00216-011-5420-6
dc.relation.publisherversionhttp://dx.doi.org/10.1007/s00216-011-5420-6spa


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem