Mostrar el registro sencillo del ítem

Strategies for the connection of distributed power generation units to distorted networks

dc.contributor.authorBlanco Charro, Cristian 
dc.contributor.authorDíaz Reigosa, David 
dc.contributor.authorBriz del Blanco, Fernando 
dc.contributor.authorGuerrero Muñoz, Juan Manuel 
dc.date.accessioned2016-01-11T12:01:31Z
dc.date.available2016-01-11T12:01:31Z
dc.date.issued2015
dc.identifier.citationIEEE Transactions on Industry Applications, 51(5), p. 4111-4120 (2015); doi:10.1109/TIA.2015.2439639
dc.identifier.issn0093-9994
dc.identifier.urihttp://hdl.handle.net/10651/34484
dc.description.abstractConnection of distributed power generators (DPGs) to a utility grid requires the synchronization between the DPG and the grid voltages with the goal of controlling the power flow and limiting the currents at instant that the switch or breaker closes. Synchronization methods typically match the positive sequence voltage component of the two systems being connected, the connection being realized when the error is smaller than a preset threshold. While synchronization using the positive sequence voltage provides adequate results in the case of undistorted grid voltages, it can be inadequate if the grid is polluted, e.g., in case of weak grids. Instantaneous voltage mismatches between the DPG and the grid, e.g., due to the harmonic content or unbalances in the grid and/or DPG voltages..., at the instant that the breaker closes, can cause overcurrents and result in unwanted protection tripping or equipment damage, even if the corresponding positive sequence voltages perfectly match. This paper analyzes the synchronization and connection of DPGs to highly distorted grids with the goal of limiting the overcurrent due to voltage mismatch. Once the connection is realized, a transition to the conventional positive sequence voltage based synchronization occurs, as this is adequate to control the power flow in steady statespa
dc.description.sponsorshipMinistry of Science and Innovation [MICINN-10-CSD2009-00046]; Ministry of Economy and Competitiveness [MINECO-13-ENE2013-48727-C2-1-R]; Personnel Research Training Program - Regional Ministry of Education and Science of the Principality of Asturias [BP11-107]spa
dc.format.extentp. 4111-4120spa
dc.language.isoengspa
dc.publisherIEEEspa
dc.relation.ispartofIEEE Transactions on Industry Applications, 51(5)spa
dc.rights© IEEE
dc.titleStrategies for the connection of distributed power generation units to distorted networksspa
dc.typejournal articlespa
dc.identifier.doi10.1109/TIA.2015.2439639
dc.relation.projectIDMEC/MICINN-10-CSD2009-00046
dc.relation.projectIDMEC/MINECO-13-ENE2013-48727-C2-1-R
dc.relation.projectIDFICYT/BP11-107
dc.relation.publisherversionhttp://dx.doi.org/10.1109/TIA.2015.2439639spa
dc.rights.accessRightsopen accessspa
dc.type.hasVersionAM


Ficheros en el ítem

untranslated

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem